Cambridge Microprocessor Systems Ltd home buttonCambridge Microprocessor Systems Ltd company profile buttonCambridge Microprocessor Systems Ltd order buttonCambridge Microprocessor Systems Ltd contact buttonCambridge Microprocessor Systems Ltd products buttonCambridge Microprocessor Systems Ltd latest news buttonCambridge Microprocessor Systems Ltd downloads buttonCambridge Microprocessor Systems Ltd example code buttonCambridge Microprocessor Systems Ltd support buttonCambridge Microprocessor Systems Ltd faq buttonCambridge Microprocessor Systems Ltd links button
CMS Home Cambridge Microprocessor Systems nav arrow Support
Cambridge Microprocessor Systems nav button off
Cambridge Microprocessor Systems nav button off
Cambridge Microprocessor Systems nav button off
Cambridge Microprocessor Systems nav button off
Cambridge Microprocessor Systems nav button off
Cambridge Microprocessor Systems nav button off
Cambridge Microprocessor Systems nav button off
Cambridge Microprocessor Systems nav button off
Cambridge Microprocessor Systems nav button off
Cambridge Microprocessor Systems nav button off
Cambridge Microprocessor Systems nav button off

Micro-Module or Micro-Midget support

If you have problems when using the Micro-Module/Midget check the following:

  1. Is power applied correctly (ie +5 is greater than 4.8 Volts above 0V)?.
  2. Is the EPROM fitted correctly? Check the legs are not folded underneath the EPROM, check that the EPROM links are correct for the size of EPROM you are using.
  3. Is the default serial port off the board? If YES then check that the serial port is connected to the Micro-Module/Midget and that the address is set correctly (see expansion serial port documentation).
  4. Have you selected to correct COM port on your PC (if applicable)?.
  5. Is the Module/Serial port connected to the selected COM port?.
  6. Check that you are running a suitable terminal program using the correct serial and the port parameters are set correctly (9600,8,1,n by default).
  7. Have you disabled the watchdog timer?
  8. Fit the standard shipping EPROM and turn the board on again. If the board now responds correctly then check that the LST file is correct and all files required are included. Check that the sysinit file is correct. All device names are UPPER CASE and all programs are LOWER CASE.
  9. If the Module is able to transmit data but not receive, check that you have not installed a SERIAL mouse on the same COM port as you are using for the Module. This will probably be in CONFIG.SYS or AUTOEXEC.BAT. If you have installed a serial mouse either use a different COM port or comment out the relevant lines and reset the PC. Serial mouse drivers often disable the transmitter in the PC serial port.
  10. Try using Hyper Terminal or Windows Terminal. These packages do not require the CTS/RTS handshaking. If the Module works in these and not the supplied terminal, check your serial cables to ensure that the handshaking lines are connected.
  11. If you can not communicate with the Module, try a another P.C.


If the Module still does not respond correctly, write a full description of the fault, any error messages, etc. and fax it to Technical support or email support@cms.uk.com.

If you feel that the product is faulty please download and complete a Returns Application form before returning the product for repair.



Although Cambridge Microprocessor Systems Ltd is committed to supplying its customers with a standard well tested product, errors and bugs can always be found in even the most widely used software packages. If you find any errors or bugs please let us know by sending an email to support@cms.uk.com. All reported errors will receive a response from one of our engineers.